This technical training course is specially designed for Field Service Engineers working with Independent Service Organizations. On the other hand, Biomedical Technicians and Engineers or other technical staff at the hospitals who would like to do the first line service in their nuclear medicine departments are also welcomed.
This course aims to bring the student at a technical level so that he can perform periodic maintenance, quality assurance and calibrations with confidence. By the end of the training, student will gain the capability of troubleshooting on the ECAM ans Symbia E gamma camera systems.
During the course period, you will join hands on practical sessions and find chance to play(!) with the actual equipment itself. At these sessions, you will gain confidence and in depth knowledge about the equipment.
Like in all Siemens modalities, you will discover how simple to view and filter the so called Siemens Event Viewer(error logs). But, you will quickly figure out that, unlike other Siemens modalities, the event viewer is not very helpful in case of a failure. So, we will teach you the right starting point, in case of motion and detector failuers.
You will also learn the differences between different Siemens detectors in the market, installation tips&tricks, PM-tube replacement, corrections, software (Syngo) loading and many more useful topics about ECAM and Symbia E gamma cameras.
This course covers the following gamma cameras;
- ECAM Single Head
- ECAM Dual Head
- Symbia E
This course covers the following scintillation detectors;
- HD3C Detector
- HD3R Detector
- Duet Detector (1 inch)
- HD4R Detector
- Foresight Detector
| Duration |
|---|
| 1 Week |
| Method of Delivery |
| Theoretical sessions in classroom |
| Practical sessions on the equipment |
| Supplied Materials |
| Handouts, Slide Shows, Electronic Documentation |
| Prerequisite |
| Basic understanding of molecular imaging principles |
| Previous experience on other NM brands is a plus |
| Covered Topics |
|---|
| Overview of NM Theory |
| Siemens ECAM Breakdown |
| Service Menu Navigation |
| ECAM Mechanical |
| Gantry Front |
| Gantry Rear |
| Front Bed, Rear Bed |
| C-Frame |
| Power |
| Motion (Gantry Rotate, Gantry Left/Right, Radial in/out, Patient Bed in/out/up/down) |
| E-STOP |
| Manual Mode, in case of motion failures |
| Calibrating Gantry Motions |
| Computers (ESoft and SNAC) |
| Detectors and differences |
| Detector Tuning |
| Periodic Maintenance |
| Installation, Tips&Tricks |
| PM-Tube Replacement, Tips&Tricks |
| Software (Syngo) Loading ESoft/SNAC |
| Software Tips&Tricks (Configuration, Backup/Restore, important batch files, dicom connectivity, licensing, etc.) |
Disclaimer:
Fox Academy is an independent training organization and do not have any organic or business relations with equipment manufacturers.
The use of manufacturer brand names and their model names and/or any mention of specific commercial products or services herein is solely for educational purposes and does not imply endorsement by Fox Academy or our partners, nor discrimination against similar brands, products or services not mentioned.